| Product type |
Ultrasonic Flow Meter (Clamp-on or Inline) |
| Product family name |
OPTISONIC Series (Krohne) |
| Pipe sizes |
DN15 to DN4000 (½” to 160″) for clamp-on; DN25 to DN3000 (1″ to 120″) for inline |
| Measurement principle |
Transit-time differential ultrasonic measurement (multi-path for high accuracy) |
| Measured media |
Liquids (conductive/non-conductive), gases, steam; suitable for cryogenic and high-temperature applications |
| Process pressure |
Up to PN200 / ASME Cl 1500 for liquids; gas versions up to PN450 / ASME Cl 2500 |
| Process temperature |
Cryogenic: down to -200°C (-328°F)
High temp: up to +250°C (+482°F) for liquids; gas up to +180°C (+356°F)
Special versions: up to +600°C (+1112°F) for thermal oil |
| Accuracy |
Inline: ±0.3% of measured value (under reference conditions)
Clamp-on: typically ±1-2% of reading
Repeatability: ±0.2% |
| Optional Outputs |
Temperature and pressure inputs for energy or mass flow calculation
Digital communication: HART®, Modbus, FOUNDATION™ Fieldbus, PROFIBUS-PA/DP
Analog: 420 mA, pulse, frequency outputs |